The Readings screen of the MACO menu shows the meter readings that Market Communication receives from the distributor. It has four tabs: Integrated files, Meter reading, Integration R6X and Flow R6X.
This page describes the two R6X tabs and how to create a manual meter reading from the Meter reading tab. The R6X tabs show the data loaded into Market Communication from the R6X flows R64, R64B, R66 and R66B: indexes and maximum power.
Integration R6X tab
This tab lists the records loaded into Market Communication from the R6X flows, one row per record. The columns are:
-
PDL: the point of delivery.
-
Error code and Error label: the processing error of the record, if any.
-
Flow: the flow the record comes from.
-
Update date: the date Market Communication last processed the record, if any.
-
Status: the processing status of the record.
Use the filters above the list to filter on any of these columns.
Expand a row to see the details of the record: PDL, Error code, Error label, Status, User, Update date, and the Creation date, Loading date and File name of the file it came from.
The menu at the end of each row includes these actions:
-
View content: opens a pop-up with the content of the record.
-
Cancel: abandons the record. Once you confirm, its status becomes Abandoned.
-
Mark to treat: once you confirm, the status of the record goes back to To Treat.
Flow R6X tab
This tab lists the readings integrated from the R6X flows, one row per reading. The columns are:
-
PDL: the point of delivery.
-
Metering date: the date of the reading.
-
Market calendar and Provider calendar: the distributor's and the provider's calendars of the reading, if any, as identified by the distributor.
-
Market dial and Provider dial: the distributor's and the provider's calendars of the reading, if any: as defined in Market Communication when the reading has dials on that calendar, otherwise as identified by the distributor.
-
Case ID: for a reading of the R64 or R64B flow, the publication identifier of the file sent by the distributor.
-
Max power: the maximum power sent with the reading, if any.
-
Creation: the date the reading was created in Market Communication.
-
Treatment op.: the treatment operation of the reading, if any.
Use the filters above the list to filter on any of these columns.
Expand a row to see the dials of the reading, if any. For each dial, the table shows its Type, ID Cadran, Index and Vraisemblance index.
Creating a manual meter reading
When an automatic reading is missing, wrong or incomplete, you can create a manual reading from an existing reading of the same point of delivery. The form is pre-filled from that reference reading.
-
In the Meter reading tab, filter on the POD to list the readings of the point of delivery.
-
Tick the reading to use as the reference. Tick one reading only.
-
Click Create reading.
-
Check the pre-filled fields, complete the reading data and the dial details as described below, then click Save.
Reading data
The upper part of the form holds the data of the reading:
-
POD: the point of delivery of the reference reading. It cannot be changed.
-
Reading ID: a new ID starting with MAN_ is proposed from the ID of the reference reading. You can change it.
-
Reading date: enter the date of the new reading. It must be later than the Previous reading date; otherwise the form shows The reading date must be later than the previous reading date.
-
Previous reading ID and Previous reading date: the ID and the date of the reference reading.
-
Contractual sequence num, Hourly seasonal structure ID, ID cal. D ENEDIS, ID cal. F ENEDIS, D cal. ID, F cal. ID, Client type, Opening services level, Counter type and Event origin: copied from the reference reading.
-
Reading status: INITIAL by default.
-
Consumption nature: REAL by default.
-
Reading reason: CYCL by default.
-
Index nature: SELF-READING by default.
-
Status: To Treat by default.
-
Flow: the flow of the reference reading, or R15 when the reference reading has none.
-
Case ID, Contractual situation ref., Rectification reason and Next theoretical reading date: enter or change them if needed.
Fields marked with an asterisk are mandatory. When Flow is R15, ID cal. D ENEDIS, ID cal. F ENEDIS, D cal. ID, F cal. ID, Client type and Opening services level are mandatory too.
Dial details
The Details tab below the reading data holds one block per dial of the reference reading. For example, it holds a single block when the reference reading has one base dial, and four blocks when it has peak and off-peak dials on both the distributor's and the provider's calendars.
Each block is pre-filled from the matching dial of the reference reading: Calendar type, Temporal class, ID Meter, Consum. ID, Metering side, Cadran number capacities, Reset to zero indicator, Reading coefficient (1 by default) and Serial number. Previous index takes the index value of the reference reading.
In each block, enter the new Index value of the dial, and its Consumption if needed.